04/14
3X Ø0.27" [Ø6.7]
11.0" [278]
A PORT
B PORT
1.00" [25.4]
2.42" [61.5]
8.79" [223.2]
8.8" [224]
0.94" [23.8]
2.13" [54.0]
3.81" [96.9]
2.19" [55.6]
3.94" [100.0]
ADJUSTABLE RELIEF (1500 PSI (103 BAR) FACTORY SETTING)
Pressure Drop vs. Flow
0
5
10
15
20
25
30
35
40
45
1.0 3.0 6.0 9.0 12.0 15.0 18.0 20.0
Flow (gpm)
Pressure Drop (psi)
0.0
0.3
0.7
1.0
1.4
1.7
2.1
2.4
2.8
3.1
3.8 11.4 22.7 34.1 45.4 56.8 68.1 75.7
Flow (lpm)
Pressure Drop (bar)
P to A or B, and A or B to T
Neutral Flow (T4 Spool)
Pressure Drop vs. Flow
0
5
10
15
20
25
30
35
40
45
1.0 3.0 6.0 9.0 12.0 15.0 18.0 20.0
Flow (gpm)
Pressure Drop (psi)
0.0
0.3
0.7
1.0
1.4
1.7
2.1
2.4
2.8
3.1
3.8 11.4 22.7 34.1 45.4 56.8 68.1 75.7
Flow (lpm)
Pressure Drop (bar)
P to A or B, and A or B to T
Neutral Flow (T4 Spool)
GENERAL INFORMATION:
Pipe Thread Sealant - Warranty is void when Teflon tape is used to seal pipe threads. This is because Teflon tape is a
friction reducing agent which allows customers to over-torque fittings. We recommend using a sealant that does not include
friction reducing agents i.e. Lead Plate.
Spool Information - All AO’s are built with Iosso plated spools to help prevent the spools from locking up when they are in
a corrosive environment. For highly corrosive environments, i.e. marine applications, we recommend using a stainless steel
spool. To order a valve with a stainless steel spool simply add “SS” to the end of the model code.
DIMENSIONAL DATA:
FLOW & PRESSURE INFORMATION: